Light Microscopy
Andor
SD1 - Andor Spinning Disc
Category
Spinning disk
Facility
LMF MPI-CBG
Location
MPI-CBG,
038A
Link to Booking
Description
Fast, "real-time" confocal imaging.
Laser equipment: 488 nm solid-state Coherent Sapphire (75mW), 561 nm solid-state Cobolt Jive (75mW) + 640 Coherent Cube (40mW).
Suitable for confocal imaging of EGFP, mCherry, dTomato, Draq5 and the like with high temporal and spatial resolution..
Suitable for Specimen
- Fixed samples
- Live samples
Suitable for Technique
- 3D imaging
- Laser cutting/ ablation
Microscope Stand
OLYMPUS
IX 71, inverted stand, motorized objective revolver, motorized z focus
Additional Magnification
Optovar 1x / 1.6x, manual
Z Focus Device Additional
PIFOC Piezo Nanofokussystem
Objectives
-
Immersion:Air
-
Coverslip Thickness:0.17 mm
-
Working Distance:3.1 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLSAPO10X2
-
Coverslip Thickness:0.17 mm
-
Working Distance:2.1 mm
-
Nomarski Prism:A
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLFLN20X
-
Immersion:Air
-
Coverslip Thickness:0.17 mm
-
Working Distance:0.51 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLFLN40XPH
-
Immersion:Air
-
Collar:coverslip correction
-
Coverslip Thickness:0.11-0.23 mm
-
Working Distance:0.18 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLSAPO40X
-
Immersion:Water
-
Collar:coverslip correction
-
Coverslip Thickness:0.13-0.25 mm
-
Working Distance:0.25 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UAPON40XW340
-
Immersion:Oil
-
Collar:NA correction
-
Coverslip Thickness:0.17 mm
-
Working Distance:0.12 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLFLN60XOIPH
-
Immersion:Water
-
Collar:coverslip correction
-
Coverslip Thickness:0.13-0.21 mm
-
Working Distance:0.28 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLSAPO60XW
-
Immersion:Oil
-
Coverslip Thickness:0.17 mm
-
Working Distance:0.13 mm
-
Thread:RMS (20.32×0.71 mm)
-
Tube Length:∞
-
OLYMPUS Order Number:UPLSAPO100XO
Condenser
BF, Ph2, Ph3, DIC I, DIC II,
NA 0.55, working distance 27 mm, manual
Fluorescence Filter Cubes
- empty
- BP 377/50 (BP 352-402), excitation filter, bandpass, AHF
- LP 409, dichromatic mirror, longpass, AHF
- BP 447/60 (BP 417-477), emission filter, bandpass, AHF
- LP 405, dichromatic mirror
Additional Filter(s)
Andor
emission filter wheel
- BP 525/30 (BP 510-540), emission filter, bandpass
- BP 624/40 (BP 604-644), emission filter, bandpass
- BP 445/40 (BP 425-465), emission filter, bandpass
- BP 512/23; BP 630/91 (BP 497-558; BP 612-693), emission filter, double bandpass
- BP 525/30; BP 650/? (BP 510-540; BP 650/?), emission filter, double bandpass
- BP 605/70 (BP 570-640), emission filter, bandpass
- LP 488 Razor edge, emission filter, longpass
- LP 568 Razor edge, emission filter, longpass
- LP 635, emission filter, longpass
Transmitted Illumination
- Lamp (Halogen, 100W)
Fluorescence Illumination
- HBO (100W, Mercury arc lamp)
- 488nm (integrated Laser DPSS)
- 561nm (integrated Laser DPSS)
- 640nm (Laser DPSS)
Camera
-
Port, Magnification:left side port
-
Sensor Size:8.2 x 8.2 mm
-
Maximum Frame Size:512 x 512 dexels
-
Bit Depth:14 bit
-
Max Full Chip Frame Rate:35-549 fps
-
Port, Magnification:right side port
-
Sensor Size:16.6 x 14 mm
-
Maximum Frame Size:2560 x 2160 dexels
-
Bit Depth:16 bit
-
Max Full Chip Frame Rate:30 fps
XY Stage
Prior ProScan III, motorized
Scan Head
- Maximum Spinning Disk Rotation Speed: 1500 - 10.000 rpm
- Physical Pinhole Diameter: 50 µm
- Physical Pinhole Spacing: 250 µm
Incubation
stage top incubator
(Bachhofer chamber, H. Saur)
Feature
Heating
Feature
Heating
Additional Equipment
Micropoint - 405nm laser for ablation